SOLEIL: Beamline Flux and Coherence Budgets of the French 2.75 GeV Source

Year: 2026
Type: article
Abstract: This paper recomputes the principal source budgets of SOLEIL from its published headline parameters: a beam energy of 2.75 GeV, a stored current of 0.5 A, a circumference of 354.1 m and a dipole field of 1.71 T. The bending radius implied by those inputs is 5.36 m, giving a critical energy of 8.60 keV against a published value of 8.6 keV, an energy loss per turn of 943 keV and a total radiated power of 472 kW against 470.0 kW published. A reference undulator of 2.4 cm period and 1 T peak field has parameter K of 2.24 and a fundamental at 0.85 keV, with the third and fifth harmonics reaching 2.6 keV and 4.3 keV. At the reference wavelength of 40.0 nm the diffraction-limited emittance is 3183.1 pm rad, so the stored beam, with a horizontal emittance of 3900.0 pm rad, carries a coherent fraction of about 0.816. Computed and published values agree at the level expected once lattice averages and insertion-device loads are accounted for, which makes the published parameter set an internally consistent basis for planning experiments at this facility.