Trapping more seeing more, benchmarking a new trap column for low-input proteomics

Year: 2026
Type: preprint
Abstract: Nanoflow liquid chromatography coupled to mass spectrometry (LC-MS) has become central to low-input and single-cell proteomics (SCP), where trap-and-elute workflows offer sample loading flexibility and analytical column protection but introduce additional dead volume, surface area, and a largely uncharacterized trade-off between flush direction and chromatographic performance. Here, we present a systematic, iterative benchmarking study of a purpose-built family of NanoShield™ trap columns against the established PepMap™ Neo trap cartridge and direct injection. Using a standardized workflow built on a commercial HeLa digest standard, we evaluated performance across two mass spectrometry platforms, multiple LC gradient lengths, both flush directions, and a range of sample input amounts and injection volumes. Shortening of the NanoShield™ packed bed, from an initial 5 cm format to a 1.2 cm format, closed a substantial sample loading time penalty and largely eliminated a pronounced forward-flush performance deficit, while remaining superior to the PepMap™ in reverse-flush mode and approaching direct injection level identification numbers, peak width, and quantitative precision. A next-generation NanoShield™ featuring a stationary phase with larger pore size further narrowed the residual forward-flush penalty. These results demonstrate that trap column bed length and stationary phase chemistry are key, partially independent design levers for closing the performance gap between trap-and-elute and direct injection workflows, and provide practical, present-day guidance for trap column selection and operation in low-input proteomics. HIGHLIGHTS Iterative, feedback-driven benchmarking narrowed the performance gap between trap- and-elute and direct injection workflows for low-input proteomics. Shortening the NanoShield™ trap column from 5 cm to 1.2 cm eliminated most of the loading time penalty and forward-flush peak broadening vs the PepMap™ Neo trap cartridge. NanoShield™ trap column with a stationary phase featuring larger pore size (300 Å) further reduced the residual forward-flush penalty. In reverse-flush mode, the optimized short NanoShield™ trap column approached direct injection level IDs, peak width, and quantitative precision while retaining higher throughput. NanoShield™’s advantage over PepMap™ held across a range of sample inputs and injection volumes. Trap column length and pore size emerge as key design levers for closing the forward-flush gap, offering practical guidance for trap column selection and use.
Language: English
Subfield: Spectroscopy
Field: Chemistry
Open Access status: green
OpenAlex ID: W7233822514
Cites: 16
Cited by:
Related to: 10