CT-Derived Leaflet Sizing Discrepancy Is Associated With Valve-Related Events After Aortic Valve Neocuspidization
Year: 2026
Type: preprint
Study design: Observational Study
Abstract: Background Accurate leaflet sizing is essential for aortic valve neocuspidization (AVNeo), yet objective anatomical references for selecting leaflet size remain limited. We investigated whether the discrepancy between a patient-specific computed tomography (CT)-derived anatomical reference and intraoperatively selected leaflet size was associated with valve-related events after AVNeo and assessed the reproducibility of the CT-derived measurements. Methods We retrospectively investigated 32 consecutive patients who underwent AVNeo with preoperative ECG-gated CT. A CT-derived reference leaflet size was geometrically estimated from the intercommissural distance. Sizing discrepancy was defined as the difference between the CT-derived reference and intraoperatively selected leaflet size, with maximum Δ representing the largest discrepancy among the three cusps. Interobserver reproducibility was assessed using independent measurements by a radiologic technologist, an experienced cardiovascular surgeon, and a cardiovascular surgery trainee. Associations with valve-related events were assessed using Cox proportional hazards and receiver operating characteristic analyses, and interobserver reliability was evaluated using intraclass correlation coefficients. Results During a median follow-up of 23 months, valve-related events occurred in eight patients. Greater maximum Δ was associated with valve-related events (hazard ratio, 1.39 per 1-mm increase; 95% confidence interval [CI], 1.09–1.78; P = 0.004). Exploratory receiver operating characteristic analysis identified 4.9 mm as the optimal cutoff (area under the curve [AUC], 0.818; 95% CI, 0.647–0.989), and patients with maximum Δ ≥ 4.9 mm had lower valve-related event-free survival (log-rank P = 0.020). Interobserver reliability was moderate to good, with intraclass correlation coefficients of 0.726 (95% CI, 0.339–0.881), 0.703 (95% CI, 0.231–0.879), and 0.832 (95% CI, 0.516–0.932) for the right coronary, left coronary, and noncoronary cusps, respectively. Observer-specific AUCs for maximum Δ were 0.776 for the radiologic technologist, 0.818 for the experienced cardiovascular surgeon, and 0.667 for the cardiovascular surgery trainee. Conclusions Greater discrepancy between the CT-derived anatomical reference and intraoperatively selected leaflet size was associated with subsequent valve-related events after AVNeo. CT-derived measurements showed moderate-to-good interobserver reliability, although discriminatory performance varied among observers. These findings support further investigation of CT-derived anatomical sizing as a patient-specific reference for AVNeo, while highlighting the need for standardized measurement methods and external validation in larger cohorts. Clinical trial registration Not applicable. This study was a retrospective observational study and was not a clinical trial.
Source: Research Square
Authors: Koki Yokawa(Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Visualization, Writing – original draft, Writing – review & editing), Yosuke Tanaka(Data curation, Investigation, Writing – review & editing), Tomoaki Ishihama(Data curation, Investigation, Writing – review & editing), Kaede Uesugi, Ko Ishimoto, Tomonori Higuma, Kazunori Yoshida, Hidefumi Obo, Hidetaka Wakiyama
Institution: Kakogawa Central City Hospital
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7233865412
