Early risk stratification for ventilator-associated pneumonia in mechanically ventilated neonates: development and external validation of a multicenter prediction model
Year: 2026
Type: article
Study design: Observational Study
Abstract: Ventilator-associated pneumonia (VAP) is an important healthcare-associated infection in mechanically ventilated neonates. Early identification of high-risk neonates may help guide targeted prevention in neonatal intensive care units. This study aimed to develop and externally validate a prediction model for VAP using routinely available early clinical and laboratory variables. This multicenter retrospective study used data from five hospitals in China: four for model development and one independent hospital for external validation. Eligible neonates remained invasively ventilated for more than 48 h, and risk was estimated at 48 h after intubation using clinical variables available before intubation and the first laboratory measurements obtained within 24 h. Univariable logistic regression and least absolute shrinkage and selection operator regression were used for predictor screening, followed by multivariable logistic regression. Discrimination, calibration and clinical utility were assessed using receiver operating characteristic curves, calibration curves, the Hosmer–Lemeshow test, decision curve analysis and clinical impact curves. Bootstrap bias-corrected calibration curves were obtained using 1000 resamples in both cohorts. The study was retrospectively registered in the Medical Research Registration Information System (registration no. MR-50-26-037954). A total of 669 neonates were included: 363 in the development cohort and 306 in the external validation cohort. VAP occurred in 124 and 100 neonates, respectively. Five predictors were retained: white blood cell count, hemoglobin, albumin, C-reactive protein and pre-intubation sepsis. The model showed good discrimination, with an area under the curve of 0.854 (95% confidence interval, 0.813–0.895) in the development cohort and 0.821 (95% confidence interval, 0.766–0.876) in the external validation cohort. Calibration was acceptable in both cohorts. At the fixed cutoff of 0.329, sensitivity and specificity were 69.0% and 85.4%, respectively, in the external validation cohort, and VAP occurred in 69.7% of high-risk neonates compared with 15.0% of low-risk neonates. A five-variable model showed good discrimination and acceptable calibration for early VAP risk stratification and may support risk-informed surveillance and reinforcement of preventive practices; prospective impact evaluation is required before routine implementation.
Language: English
Topic: Nosocomial Infections in ICU
Field: Medicine
Domain: Health Sciences
Keywords: ventilator-associated pneumonia, neonates, mechanical ventilation, risk stratification, prediction model, early risk prediction, white blood cell count, C-reactive protein, hemoglobin, serum albumin, nosocomial infections, neonatal intensive care, infection control, external validation, model calibration, discrimination (statistics), clinical utility, decision curve analysis
Open Access status: gold
Estimated APC paid: $3,290
OpenAlex ID: W7234269484
