Retrospective comparison of the revision rate of multiple shunt valve systems in adult and pediatric patients
Year: 2026
Type: article
Study design: Observational Study
Abstract: PURPOSE: Ventriculoperitoneal shunt implantation remains the primary treatment modality for hydrocephalus. They are susceptible to complications and subsequent revision surgeries. This study aimed to compare different valve systems regarding their revision rates in pediatric and adult patients. METHODS: 187 patients underwent primary VP shunt placement at our institution between 2016 and 2020. Due to significant differences in overall observation time, the one-year revision rate was defined as the primary endpoint. We conducted retrospective analyses of overall and one-year revision rates, as well as revision-free survival, according to valve type, as well as demographic and etiological factors. RESULTS: No significant differences in revision rates were observed between programmable and non-programmable valves (p=0.608) or between gravitational and non-gravitational devices (p=0.606). Slit valves were associated with a significantly lower one-year revision rate compared to all other valve types (10% vs. 30.6%, p=0.024), a finding that remained significant in multivariate analysis (p=0.039). In time-to-event analysis, however, the difference between slit and non-slit valves did not reach statistical significance (Cox regression p=0.224; log-rank p=0.149). Pediatric patients demonstrated higher revision rates in univariate analysis (56% vs. 22.8%, p<0.001), though this did not persist in multivariate analysis (p=0.209). A shorter revision-free survival in pediatric patients was demonstrated (p=0.002). Normal pressure hydrocephalus (NPH) was associated with a markedly lower revision rate (0% vs. 29.8%, p=0.007). Prior cerebrospinal fluid diversion was associated with higher revision rates in univariate analysis, though without independent significance in multivariate analysis. CONCLUSION: Slit-valve devices and NPH diagnosis were associated with significantly lower one-year revision rates, although the slit-valve effect was not significant in time-to-event analysis and should be regarded as hypothesis-generating. Programmable versus non-programmable valves and gravitational devices did not yield significant differences. Pediatric patients demonstrated shorter revision-free survival compared to adults.
DOI: 10.1055/a-3003-3702
Language: English
Subfield: Clinical Neurology
Field: Medicine
Domain: Health Sciences
Open Access status: hybrid
OpenAlex ID: W7234350036