Work

In Vivo Ankle Tendon Quantification Using Ultrashort Echo Time Magnetization Transfer Imaging

Year: 2026
Type: article
Abstract: OBJECTIVES: To quantitatively assess in vivo ankle tendons using less magic angle-sensitive 3-dimensional ultrashort echo time magnetization transfer (UTE MT) imaging and to compare its intersubject variability with UTE T2* mapping in healthy volunteers. MATERIALS AND METHODS: Thirty healthy volunteer ankles were examined on a 3T MRI system using a standardized clinical protocol with additional 3D UTE MT and 3D multi-echo UTE T2* sequences (acquisition times: 4:16 and 9:52 minutes, respectively). Nine major ankle tendons were semi-automatically segmented to extract quantitative UTE MTR and UTE T2* values for each tendon. Variability for each sequence was assessed using the coefficient of variation (CV), and differences in CV were evaluated primarily with a paired bootstrap of the CV ratio and secondarily with a modified signed log-likelihood ratio (MSLR) test, both with Holm correction. Within-tendon angular dependence was assessed using local tendon fiber angles relative to B0. RESULTS: Absolute quantitative values differed between tendons, with the Achilles tendon demonstrating the lowest T2* values (2.15±0.43 ms) and highest MTR values (0.44±0.08), whereas smaller positional tendons showed higher T2* and lower MTR values. UTE MTR demonstrated lower overall variability compared with UTE T2* values across the 9 assessed tendons (overall CV UTE MTR: 18.0%±4.2% vs. UTE T2*: 33.7%±8.9%, mean±SD, n=9). In the paired bootstrap analysis with Holm correction, UTE MTR showed significantly lower variability than UTE T2* in 6 of 9 tendons, with the largest differences in the extensor digitorum longus, peroneus brevis, and flexor hallucis longus tendons (T2*/MTR CV ratio, 2.74, 2.60, and 2.48; all Holm-adjusted P≤0.015); MSLR results were consistent. Between 0 degree and the magic angle, UTE T2* increased by 79% (95% CI: 64%-95%), whereas UTE MTR decreased by 9% (95% CI: 7%-11%). UTE MTR consistently demonstrated reduced dispersion and narrower value distributions compared with UTE T2*. CONCLUSIONS: In vivo ankle tendon quantification using UTE MT is feasible within clinically acceptable acquisition times and shows significantly lower intersubject variability than UTE T2* mapping in most tendons, with reduced susceptibility to the magic angle effect. UTE MT represents a promising approach for quantitative assessment of tendon structure in vivo.
Language: English
Field: Medicine
Open Access status: hybrid
OpenAlex ID: W7234355605
FWCI:
Cites: 50
Cited by:
Related to: 10