Work

Physics-anchored fault-cell localization in electric vehicle battery packs with variable cell counts

Year: 2026
Type: article
Abstract: Identifying a faulty cell from battery-management records is difficult when operating trends affect all cells and different diagnostic indicators favour different candidates. Here we present PhyFuseCell, a physics-anchored ranking method for packs with variable cell counts. Both branches reference cell voltages to the pack median: one characterizes charge-residual magnitudes and trends, while the other learns normalized discharge patterns. A shared cell encoder and scorer, together with valid-cell masking, accommodate different pack sizes. The evidence scores are standardized within each pack and combined with equal weights. On CH-BatteryGen packs with 28 or 124 cells, the compact implementation achieved the highest mean Top-1 localization accuracy among the evaluated methods, at 98.0 ± 2.7% across five vehicle-held-out splits, 7.0 percentage points above a validation-tuned clustering baseline. Paired predictions showed how complementary evidence corrected competing cell rankings. In self-discharge transfer without target-group training, adding target-pack charge evidence increased mean accuracy from 61.0 to 83.8% for 28-to-124-cell transfer and from 66.3 to 94.7% in reverse. These results support organizing physical and temporal evidence at the cell level to improve fault localization across the evaluated pack sizes.
Author: Fei Fang
Language: English
Open Access status: gold
Estimated APC paid: $2,690
OpenAlex ID: W7234387395
FWCI:
Cites: 43
Cited by: