Effect of Liquid Nitrogen Cooling on Machinability and Tool Wear Mechanisms in Cutting CGI-400
Year: 2026
Type: article
Abstract: This study systematically investigates the performance of liquid nitrogen cooling in machining compacted graphite iron 400 (CGI-400), compared with conventional cutting fluid cooling, focusing on mechanical properties, cutting temperature, tool wear, and surface quality. Results indicate that liquid nitrogen cooling significantly reduces the cutting temperature by 22.38%, effectively suppresses flank wear and built-up edge formation, and demonstrates remarkable advantages at cutting lengths beyond 3000 m. Cryogenic embrittlement of CGI-400 under liquid nitrogen leads to an 11.32% reduction in tensile strength, while the temperature-dependent thermal conductivity influences heat management in the cutting zone. EDS analysis reveals less material adhesion and improved coating integrity under liquid nitrogen cooling, contributing to prolonged tool life and enhanced surface finish. This research provides theoretical and practical insights into the cryogenic machining of CGI-400.
Source: MANUFACTURING TECHNOLOGY
Institution: Hangzhou Dianzi University
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W7234519950