Dual Response Matching for Conversion Between Stiffened and Unstiffened Flange Connections
Year: 2026
Type: article
Abstract: Converting stiffened flanges to unstiffened details can simplify fabrication and assembly for emergency replacement. This study proposes a dual-response assessment procedure combining global displacement and connection rotation matching with local load-transfer checks. Project-based nonlinear finite element models establish a common compression–bending reference. Normalized root-mean-square errors guide thickness selection and comparisons of flange outside diameter and bolt circle diameter. Contact evolution, interface opening and bolt-force histories explain the associated load redistribution. At an eccentricity of 125 mm, a 14 mm unstiffened flange gives displacement and rotation errors of 3.37% and 3.72%, respectively, relative to a 6 mm stiffened reference. The constant-length comparison confirms the 14 mm stiffness-matching candidate. Resistance checks at the research load target identify the need to revise its original class 8.8 M12 bolt configuration and associated connection detailing. The procedure therefore combines response-based selection with a separate component-resistance assessment for replacement design.
Source: Applied Sciences
DOI: 10.3390/app162211330
Institution: Xi'an Jiaotong University
Language: English
Subfield: Civil and Structural Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $2,896
Award: G3133951559
OpenAlex ID: W7234611903