Work

Platelet-Rich Plasma versus Injectable Platelet-Rich Fibrin: Comparative Effects on the Rate of Orthodontic Tooth Movement

Year: 2026
Type: article
Study design: Clinical Trial
Abstract: Background Prolonged orthodontic treatment remains one of the major concerns associated with comprehensive fixed orthodontic therapy. Orthodontic tooth movement is dependent on periodontal ligament remodeling, osteoclastic bone resorption, osteoblastic bone formation and vascular changes. Autologous platelet concentrates have emerged as minimally invasive biological approaches for accelerating orthodontic tooth movement. Platelet-rich plasma (PRP) and injectable platelet-rich fibrin (i-PRF) are autologous platelet concentrates with different preparation methods, fibrin characteristics and growth-factor release profiles. Aim To compare the effectiveness of locally administered PRP and i-PRF in accelerating orthodontic tooth movement during maxillary canine retraction. Materials and Methods A prospective comparative clinical study was conducted in 22 patients. standEleven patients were assigned to the PRP group and 11 patients to the i-PRF group. All patients were considered to undergo extraction-based orthodontic treatment requiring maxillary canine retraction. All patients were treated using standardized fixed orthodontic mechanics. Canine retraction was evaluated at 21, 42, 63 and 84 days. The cumulative amount of canine retraction was measured in millimeters. Mean, standard deviation and betweengroup statistical comparisons were calculated. Results At 21 days, the mean canine retraction was 0.412 ± 0.037 mm in the PRP group and 0.425 ± 0.029 mm in the i-PRF group. The difference was not statistically significant (p = 0.343). At 42 days, mean canine retraction increased to 1.091 ± 0.054 mm in the PRP group and 1.212 ± 0.037 mm in the iPRF group. The difference of 0.121 mm was statistically significant (p < 0.001). At 63 days, the mean cumulative retraction was 1.773 ± 0.061 mm with PRP and 2.075 ± 0.063 mm with i-PRF, demonstrating a statistically significant difference of 0.303 mm (p < 0.001). At 84 days, cumulative canine retraction was 2.374 ± 0.061 mm in the PRP group and 2.994 ± 0.078 mm in the i-PRF group. The difference of 0.620 mm was statistically significant (p < 0.001). Conclusion In this dataset, both PRP and i-PRF demonstrated progressive orthodontic tooth movement; however, i-PRF demonstrated a significantly greater cumulative amount of canine retraction from the sixth week onward. The findings support the potential of i-PRF as a biological adjunct for accelerated orthodontic tooth movement.
Language: English
Subfield: Orthodontics
Field: Dentistry
Open Access status: bronze
OpenAlex ID: W7234789081
FWCI:
Cites: 10
Cited by:
Related to: 10