Abstract: A stand-alone photovoltaic charger must switch from maximum power point tracking to constant-current, constant-voltage (CC–CV) charging whenever a LiFePO4 battery cannot absorb the available power. This simulation study derives design rules for this hand-over in low-cost digital chargers with a single 10–100 ms control loop. In the surplus-proportional hand-over (SPH), the charging law sets an allowable current, and the module voltage is raised above the maximum power point in surplus-proportional steps. Unlike constant power point tracking or model-based limiting, it needs no power reference or irradiance sensor. Convergence and noise analyses determine the step gain, filter, hysteresis and voltage-loop gain. SPH and eight noise-retuned baselines were compared in Simulink, Monte Carlo runs and 30 days of measured irradiance at two sites. All voltage-mode trackers harvested the same energy. At the nominal limit, SPH exceeded 1 A s of overcurrent charge in one of 800 Monte Carlo runs, or 19 without any exclusion window after load steps (other feedback controllers: 18–100%). Min-select on a filtered current reference had lower monthly totals but tracked 0.3–0.4 percentage points less efficiently. At 0.15 C, only CPG with a hold band had less overcurrent charge but stayed 7–8 times longer above the CV voltage.