Single‐Phase Inverter With Sensorless Observer Control and Multi‐Order Harmonic Compensation

Year: 2026
Type: article
Abstract: This paper proposes a sensorless control strategy for a single‐phase inverter based on a discrete‐time state observer. The proposed observer accurately reconstructs the AC‐side capacitor current, enabling capacitor current feedback without the need for a physical current sensor. To enhance power quality, a proportional–resonant (PR) controller with multiharmonic compensation is employed to suppress dominant low‐order harmonics and reduce total harmonic distortion (THD). Additionally, a one‐step‐ahead prediction scheme is adopted to mitigate digital control delays and enhance system stability. The proposed method is validated on a 2‐kW hardware prototype. Experimental results show that the output voltage THD is reduced from 11.82% to 5.18% under nonlinear load conditions, demonstrating significant improvement in output waveform quality and confirming the effectiveness of the approach.