Economic Value of Intraday Photovoltaic Power Forecast Updates for Energy Storage Dispatch in Grid-Connected Microgrids
Year: 2026
Type: article
Abstract: Grid-connected photovoltaic (PV) microgrids coordinate battery dispatch with grid purchases, and forecast errors can trigger costly emergency energy. This study evaluates a common 10-minute linear-programming model over 334 days in 2025, separating forecast source, rolling control, and added intraday releases under the stated settlement rules. Under the fixed tariff, replacing the historical seven-day mean with the official 00:00 forecast raises static cost by RMB 352,530.85; rolling control under the same forecast adds RMB 2,108.15. Adding the 06:00, 12:00, and 18:00 releases to the same rolling controller lowers cost by RMB 972,910.20 versus the 00:00-only case (6.58%) and cuts emergency energy by 50.48%. The broader S1-to-S6 reduction of RMB 618,271.20 includes all three contrasts. Across 334 paired dates, mean S1-S6 savings are RMB 1,851.11/day (95% bootstrap CI: RMB 1,320.73-2,414.82), with 71.95% from the highest-saving decile. Variable-tariff results show the same direction under a separate matched baseline. Sensitivities and data limits constrain investment claims.
DOI: 10.54097/s6trea65
Authors: Yu Liu, Sichen Lin
Institution: Southwest University of Science and Technology
Language: English
Subfield: Control and Systems Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: diamond
OpenAlex ID: W7234878866