A Bias-Augmented ARX/RLS Adaptive RST Controller for Nonideal DC–DC Buck Converters Under Line and Load Disturbances
Year: 2026
Type: article
Abstract: This study presents an adaptive RST polynomial control framework for nonideal DC–DC buck converters under line and load disturbances, explicitly accounting for pulse-width modulation (PWM) update delay. RST refers to a polynomial control structure comprising the R, S, and T polynomials. Conventional fixed-gain controllers are typically designed around a nominal operating point and may therefore lead to degraded voltage regulation, larger transient deviations, increased current stress, and reduced disturbance-rejection capability when converter dynamics vary due to load changes, input-voltage disturbances, parasitic losses, and digital implementation delays. Fixed-parameter model-based polynomial controllers may also fail to preserve the desired closed-loop dynamics when the effective converter parameters vary with the operating condition. To address these limitations, a nonideal averaged model is used to obtain an affine discrete-time input–output representation, and the effective PWM update delay is incorporated into the RST pole-placement design. The plant is identified online using a bias-augmented autoregressive with exogenous input (ARX) model with forgetting-factor recursive least squares (RLS), where the affine term separates constant operating-point and quasi-static mismatch effects from dynamic coefficients. The RST polynomials are recomputed online through a Diophantine equation, with an integral factor included for offset rejection and constant-reference tracking. The controller is experimentally evaluated on a buck converter prototype and compared with a fixed-gain proportional–integral (PI) controller under start-up, load-resistance transitions, and input-voltage transitions. In the start-up test, inductor-current overshoot is reduced from 62.5% to 12.5%, and start-up time decreases from 16.7ms to 1.6ms. For the 48V to 70V input-voltage transition, voltage overshoot decreases from 6.7V to 0.2V. The results show improved transient shaping, lower current stress, and faster recovery compared with the fixed-gain PI controller under line and load disturbances.
Source: Symmetry
DOI: 10.3390/sym18111925
Author: Fatih Evran
Institution: Düzce Üniversitesi
Language: English
Topic: Advanced DC-DC Converters
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $2,896
Award: G9001376277
OpenAlex ID: W7234923040