Work

Conventional compliance masks heavy metal exceedances in a lead-acid battery effluent treatment plant

Year: 2026
Type: preprint
Abstract: Lead-acid battery manufacturing generates complex effluents, yet conventional compliance monitoring often fails to capture the full toxicological load. This study provides a critical assessment of a treatment facility in the Ishwardi Export Processing Zone,Pabna, Bangladesh, using a split-dataset approach. The first campaign (June and July 2025) utilized effluent-only grab samples to establish baseline compliance for conventional pollutants and lead. The second campaign (November 2025) utilized six paired influent-effluent events to calculate treatment performance and generate a comprehensive eleven-metal toxicity profile. The November paired data demonstrated effective physicochemical treatment, neutralizing highly alkaline influent (mean pH 9.68 to 7.97) and recovering dissolved oxygen (2.58 to 5.87 mg L⁻¹). However, total dissolved solids (TDS) removal was highly inconsistent, averaging only 22.8% (R² = 0.51). This indicates that November TDS compliance was an artifact of lower influent loading rather than stable treatment efficacy. Critically, this conventional compliance masked severe heavy metal exceedances. Seven metals complied with ECR 2023 limits: Pb (0.015 mg L⁻¹), Zn (3.423 mg L⁻¹), As (0.0345 mg L⁻¹), Cr (0.0085 mg L⁻¹), Mn (0.0131 mg L⁻¹), Ni (0.0231 mg L⁻¹), and Hg (0.0023 mg L⁻¹). In stark contrast, three metals failed: Cu (2.075 mg L⁻¹), Cd (0.14 mg L⁻¹), and Fe (2.3 mg L⁻¹) exceeded limits by 107%, 40%, and 15%, respectively. Furthermore, Sb was detected at 0.0746 mg L⁻¹, yet lacks a defined numerical limit. Because influent metals were not measured, true metal removal efficiency could not be quantified. The findings expose a critical regulatory blind spot: conventional treatment compliance does not guarantee protection from heavy metal toxicity. The facility currently relies on influent dilution to achieve regulatory compliance, leaving the ecosystem vulnerable to episodic toxic shocks. Future monitoring paradigms must mandate paired influent-effluent metal sampling to accurately assess treatment efficacy and protect downstream aquatic ecosystems. The findings directly contribute to SDG 6 (Clean Water) and SDG 3 (Good Health) by providing the evidence base needed to modernize discharge limits and protect the Padma River ecosystem from neurotoxic and carcinogenic metal loads.
Language: English
Open Access status: green
OpenAlex ID: W7234939391
Cites: 26
Cited by:
Related to: 10