Work

Effective single-sperm cryopreservation using the cryopiece system in China: a multi-center cohort study

Year: 2026
Type: article
Study design: Observational Study
Abstract: Single-sperm cryopreservation is feasible and benefits patients with severe oligospermia or azoospermia, but previous studies were limited by single-center designs and small sample sizes. Various carriers have been reported, but their generalizability and clinical efficiency across multiple centers remain to be fully elucidated. In this retrospective cohort study, ART treatment data were collected from five Chinese reproductive centers. Couples undergoing ICSI for male factor infertility between January 1, 2015 and May 31, 2025 in these clinics were included. The same data forms were used at each participating center, and data were collected by trained staff at each coordinating clinic and transmitted electronically to the central research group. The post-thaw recovery rate was 87.27% (2,962/3,394) and the motility rate was 55.57% (1,646/2,962). The overall fertilization rate was 72.98% (1,278/1,751), with a 2PN rate of 63.16% (1,106/1,751). The clinical pregnancy rate was 52.73% (77/146) per embryo transfer, with a delivery rate of 26.03% per embryo transfer. The observed epididymal spermatozoa demonstrated significantly higher recovery and thawed motility rates (92.28% and 63.50%, respectively) compared to ejaculated (87.03% and 57.29%) or testicular (86.49% and 51.18%) spermatozoa ( P < 0.05, respectively). In contrast, the fertilization rate of epididymal spermatozoa (64.49%) was significantly lower than that of ejaculated (75.16%) and testicular (71.96%) spermatozoa ( P = 0.012). In multivariable logistic regression, only the high-quality embryo rate was independently associated with clinical pregnancy (OR 1.28, 95% CI 1.07–1.53, P = 0.008). When using thawed motile spermatozoa, assisted oocyte activation (AOA) was associated with significantly higher 2PN fertilization (68.13% vs. 58.80%, P < 0.01) and high-quality embryo rates (41.90% vs. 28.78%, P < 0.01). This multicenter study provides evidence supporting the reliability and efficiency of the Cryopiece system as a carrier for the cryopreservation of very small numbers of spermatozoa. Further prospective investigations employing standardized protocols and extended long-term follow-up are needed to confirm these findings.
Language: English
Field: Medicine
Open Access status: gold
Estimated APC paid: $3,190
OpenAlex ID: W7235003627
FWCI:
Cites:
Cited by:
Related to: 10