The Hinode EIS Active-Region Loop: A Density, Filling-Factor and Thermal-Energy Budget from Iron Line Ratios
Year: 2026
Type: article
Abstract: The Extreme-ultraviolet Imaging Spectrometer on Hinode measures active-region loop densities directly, from the ratio of two iron twelve lines that depends on density and little else. Those densities, near three times ten to the ninth per cm3, can be combined with the observed loop width and emission measure to budget the loop. This paper does so for a representative active-region loop. The measured density predicts an emission measure larger than observed, giving a filling factor of 0.22. The loop holds 3.9e+26 erg of thermal energy and cools conductively in 5.49e+03 seconds. Supplying the whole active region at the published rate needs 9.55e+03 such loops. The filling factor below unity says the loop is structured, not filled, and that structure is part of the heating story.
Author: Aldred, William Alexander
Language: English
Subfield: Astronomy and Astrophysics
Field: Physics and Astronomy
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7235272217