Multivariate calibration for on-line spectroscopic monitoring of nuclear process streams: a review from fuel reprocessing to fusion tritium plants
Year: 2026
Type: article
Abstract: On-line optical spectroscopy can monitor nuclear process streams only while its calibration remains valid. No review has covered both the fission and fusion fuel cycles or graded how far monitoring is integrated into the process. We define a six-level integration ladder (L0–L5) and apply it to 130 studies. Over half (69) stop at an on-line probe with a static model validated on simulants; 23 reach validation on real material with drift addressed, or closure of a control loop. Higher levels are associated with validation on real material rather than with the calibration algorithm. The two literatures hold complementary calibration practices.
Institution: Universitat Politècnica de Catalunya
Language: English
Subfield: Analytical Chemistry
Field: Chemistry
Domain: Physical Sciences
Open Access status: hybrid
Estimated APC paid: $3,790
OpenAlex ID: W7235336788