Acquired aortic coarctation presenting with acute paraparesis following transcatheter patent ductus arteriosus device closure in an 18‑month‑old girl: a case report

Year: 2026
Type: article
Study design: Case Report
Abstract: Background Transcatheter device closure is an established treatment for patent ductus arteriosus (PDA). Acquired coarctation of the aorta (CoA) is a rare but potentially serious complication of PDA device closure. We report a case of acquired CoA presenting with acute neurological manifestations after PDA device implantation. Case presentation An 18-month-old girl underwent transcatheter closure of a small PDA using a 6/4-mm Amplatzer Duct Occluder II (ADO II). Pre-procedural angiography showed no evidence of CoA or an anterior aortic shelf. Immediately after device deployment, the left ventricular and aortic systolic pressures were both 80 mmHg, with no measurable systolic pressure gradient, and early angiography and echocardiography showed no significant aortic obstruction. Three days after discharge, the patient developed acute bilateral lower-extremity weakness and paraparesis. Brain computed tomography showed no acute intracranial abnormality, and no dedicated spinal imaging was performed. Severe anemia (hemoglobin, 6.5 g/dL) was identified, and lower-extremity weakness improved following blood transfusion. Approximately 3 months after PDA closure, echocardiography demonstrated severe aortic isthmic obstruction with a peak gradient of approximately 45 mmHg and impaired left ventricular systolic function (LVEF, 40–43%). The patient underwent urgent surgical repair, including removal of the ADO II, resection of the narrowed aortic segment, and end-to-end anastomosis. During induction of anesthesia, she developed severe bradycardia requiring approximately 2 min of cardiopulmonary resuscitation. No lower‑extremity paralysis was observed postoperatively; however, abnormal orofacial movements developed, and electroencephalography showed no epileptiform activity. At 6-month follow-up, the neurological manifestations had resolved, while left ventricular systolic function remained mildly depressed. Conclusion Acquired CoA after PDA device closure may present with acute neurological manifestations. This case emphasizes the importance of obtaining a complete history of recent cardiac interventions when evaluating acute neurological symptoms. Careful device selection and sizing, particularly for small PDAs near the aortic isthmus, together with systematic post-procedural surveillance, may facilitate early detection of aortic obstruction and reduce the risk of severe complications.
Language: English
Field: Medicine
Open Access status: gold
Estimated APC paid: $3,090
OpenAlex ID: W7235692613
FWCI:
Cites:
Cited by:
Related to: 10