Work

ALP-ttbar Toy MC v2.4 — Post-Registration Results: Inter-Disk Service Material and Coverage-Degradation Test

Year: 2026
Type: preprint
Abstract: Post-registration results for the v2.4 toy Monte Carlo study testing the effect of inter-disk service material (cables, cooling, support structures) on the endcap photon-conversion veto for displaced light ALP → e⁺e⁻ in tt̄ events. This study adds 8 service-material bands at the midpoints of gaps between the 9 existing sensor disks, creating a 17-band endcap geometry with veto coverage C_veto ≈ 8.5% — an intermediate point between the sparse 9-disk endcap (~5.4%) and the dense barrel (~43.5%). Companion to the frozen preregistration: https://doi.org/10.5281/zenodo.24296796 Central findings: 1. Degradation increases with added material. Hard-veto degradation at 17 MeV rises from 1.06× (9-disk) to 1.09× (17-band). The ratio (d_new − 1)/(d_old − 1) = 1.56 falls within the preregistered proportionality window of 1.19–2.74 (P1, P2 confirmed). 2. Tag/HV ratio does not decrease as predicted. At 17 MeV (η = 2.0), the tag/HV ratio increased by +0.55% (1.538 vs 1.530), refuting P3's predicted decrease of ≥3%. The tag formula absorbs the additional material into its conversion-probability model, approximately cancelling the increased hard-veto rejection. 3. Hybrid strategy remains optimal. Barrel tag + endcap hard veto achieves the lowest combined degradation at 17 MeV (P5 confirmed). Hard-veto degradation varies by only 0.23% across the η scan (P6 confirmed). At 200 MeV, 17-band and 9-disk results converge to within 0.6% (P7 confirmed). Overall: 6 of 7 predictions confirmed, 1 refuted (P3). All validations (V1–V6) passed. Implemented sanity-gate checks passed; full Gate 4 barrel reproduction remains incomplete (see §6.3). Known limitation — resolution conflation (DISK_Z override). The preregistered procedure overrides endcap_sim.py's DISK_Z array with all 17 band positions. Because _measure_endcap() uses DISK_Z to assign z vertex resolution, service-material positions (passive cables/cooling) receive pixel-quality resolution (σ_z = 1.0 mm) instead of strip-quality (3.0 mm). The reported degradation values therefore reflect the combined effect of increased coverage and improved measurement resolution, and cannot be attributed to coverage alone. This software-level conflation was not anticipated at preregistration. Future directions. v2.5 (or later) will introduce a SENSOR_DISK_Z array to separate material placement from measurement resolution, isolating the pure coverage effect. Multi-seed ensembles will assess statistical significance. A service-material parameter scan will map the continuous C_veto–degradation relationship within the endcap geometry. Files: PDF report with figures, full source code (run_v24.py, endcap_sim.py, mtag_v24.py, mtag_v21.py, mtag_v22.py, coverage.py), simulation output (v24_results.npy), and PDF builder script. All computation is reproducible from python3 run_v24.py. Preregistration DOI: https://doi.org/10.5281/zenodo.24296796GitHub (preregistration): https://github.com/wspaik5/ALP-ttbar-Toy-MC-v2.4-Preregistration-Service-MaterialGitHub (results): https://github.com/wspaik5/ALP-ttbar-Toy-MC-v2.4-Post-Registration-Results-Service-MaterialBuilds on: v2.1 (doi:10.5281/zenodo.24063091, doi:10.5281/zenodo.24136462), v2.2 (doi:10.5281/zenodo.24189990, doi:10.5281/zenodo.24238224), v2.3 (doi:10.5281/zenodo.24244893, doi:10.5281/zenodo.24273586), v2.0 overview (doi:10.5281/zenodo.24056097)Motivated by: arXiv:2610.38932 Independent personal toy study, not affiliated with the authors of arXiv:2610.38932 or arXiv:2306.08686, nor with the CMS, ATLAS, LHCb or ALICE Collaborations or the FCC study. Detector numbers are assumed; only qualitative trends and ratios are meaningful.
Language: English
Open Access status: green
OpenAlex ID: W7235727812
Cites: 6
Cited by: 1
Related to: 10