Effect of radiotherapy on cardiac implantable electronic devices – evaluation of potential explanatory variables in more than a decade
Year: 2026
Type: article
Study design: Observational Study
Abstract: BACKGROUND AND PURPOSE: As the population ages, an increasing number of patients are undergoing radiotherapy with an implanted cardiac device. Therefore, ensuring the safety of these devices during radiotherapy is crucial. This study aims to analyse the effect of radiotherapy on such devices, with a particular focus on changes in lead variables. METHODS: This retrospective study examined all patients with a cardiac implantable electronic device (CIED) who underwent radiotherapy at a single institution between 2012 and 2022. Device function and associated changes in lead parameters were analysed before and after radiotherapy. RESULTS: The study cohort included 279 patients who underwent 310 courses of radiotherapy. During the 11-year study period, one device failure requiring replacement due to a software error was recorded. This occurred following irradiation with 15 MV photons. Changes in individual lead parameters were more common, occurring in almost half of all radiotherapy courses. Lead impedances were particularly sensitive to changes, with high-voltage impedances being affected more frequently (61% of impedances) than other impedances. Sensing, pacing thresholds, and battery voltage were less frequently affected, with changes occurring in fewer than 10% of the analysed leads or batteries. None of the observed changes manifested as clinical symptoms. There was no statistically significant association between radiation parameters and the observed changes in lead values with only a few courses using neutron-generating photon energies. Furthermore, no dose-effect relationship for device doses could be established. Receiving multiple courses of radiotherapy in one year or over several years did not increase the risk to the device or cause greater variation in lead variables. CONCLUSION: Only one safety event occurred during the observation period, resulting in an error rate of 0.4% across 11 years and 279 patients. Changes in individual lead parameters were more frequent. However, no clear association could be established between the observed changes and radiation parameters. In particular, changes in lead variables were not explained by the dose to the device or repeated courses of radiotherapy. Therefore, the risk to the safety and function of cardiac devices from radiotherapy appears to be small.
Source: Radiation Oncology
Institution: Medizinische Hochschule Hannover
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $3,290
Funder: Boston Scientific Corporation
OpenAlex ID: W7235951771