Work

Sensitivity Analysis of Carbon-Aware Scheduling in Cloud Computing: A Simulation-Based Study

Year: 2026
Type: article
Abstract: Data centres can trim their emissions by running flexible work while the grid is cleaner, but how large that trim appears depends heavily on the modelling choices behind the number. This study examines that dependence in a deliberately simple setting: ten synthetic jobs, 324 actual half-hourly Great Britain carbon-intensity readings across seven days (24–30 August 2026), a fixed 50 W per CPU core, and a scheduler given perfect foresight of the intensity that follows. With zero waiting allowed, estimated savings are nothing; grant up to 180 minutes and they reach about 4%. Those figures ignore each job's own deadline and the limited pool of cores. Introducing both with a mixed-integer formulation reduces the estimate to approximately 2.6%. Every value here is a deterministic best-case simulation rather than a measurement from a live data centre, so the short record, invented jobs, rough power assumption, and look-ahead signal all restrict how far the conclusions travel.
Language: English
Open Access status: green
OpenAlex ID: W7236015294
FWCI:
Cites:
Cited by:
Related to: 10