Work

Static, Dynamic and Robotic CAIS in Healed Partially Edentulous Sites: Accuracy and Chair‐Side Time

Year: 2026
Type: article
Study design: Observational Study
Abstract: AIM: To evaluate the accuracy and chair-side efficiency of static (s-CAIS), dynamic (d-CAIS), and autonomous robotic (r-CAIS) computer-assisted implant surgery in healed partially edentulous sites. MATERIALS AND METHODS: In this retrospective comparative study, 73 patients with 92 implants, treated from September 2022 to October 2024, were included (s-CAIS: 21 patients/33 implants; d-CAIS: 29 patients/32 implants; r-CAIS: 23 patients/27 implants). Pre- and postoperative CBCT scans were used to assess linear and angular deviations. The duration of chair-side preparation and drilling/implant placement was recorded for d-CAIS and r-CAIS. RESULTS: At implant level, mean platform deviations were 0.85 ± 0.38 mm (s-CAIS), 1.37 ± 0.71 mm (d-CAIS), and 0.59 ± 0.32 mm (r-CAIS; median [IQR]: 0.54 [0.30] mm); apex deviations were 1.36 ± 0.51, 1.48 ± 0.66, and 0.64 ± 0.52 mm (r-CAIS; median [IQR]: 0.53 [0.30] mm); angular deviations were 4.34° ± 2.13°, 2.53° ± 0.99°, and 1.54° ± 1.50° (r-CAIS; median [IQR]: 1.28° [1.40°]). At patient level, platform deviations were 0.88 ± 0.35, 1.37 ± 0.69, and 0.57 ± 0.29 mm; apex deviations 1.38 ± 0.44, 1.48 ± 0.65, and 0.58 ± 0.43 mm; angular deviations 4.48° ± 1.81°, 2.52° ± 0.97°, and 1.45° ± 1.30°. r-CAIS showed significantly superior accuracy compared with s-CAIS and d-CAIS (p < 0.05). Because r-CAIS data were not normally distributed, medians [IQR] were additionally calculated and are reported parenthetically. Drilling and placement time was longer for d-CAIS than r-CAIS (18.06 ± 5.54 vs. 10.81 ± 3.55 min, p < 0.05), while chair-side preparatory time did not differ (10.78 ± 2.53 vs. 9.61 ± 2.72 min, p > 0.05). CONCLUSIONS: Among the three systems, r-CAIS provided the highest accuracy and was more time-efficient during the intra-operative (chair-side) phase than d-CAIS in partially edentulous patients. CLINICAL RELEVANCE: In patients with partial edentulism, r-CAIS demonstrated superior accuracy compared with both s-CAIS and d-CAIS approaches. Furthermore, r-CAIS offered greater chair-side efficiency during the intra-operative phase than d-CAIS. This cutting-edge technology holds great promise for enhancing the precision of dental implant procedures, offering substantial benefits to both surgeons and patients.
Language: English
Subfield: Oral Surgery
Field: Dentistry
Open Access status: bronze
OpenAlex ID: W7236016624
FWCI:
Cites: 32
Cited by:
Related to: 10