Work

The Gallium Anomaly Before BEST: The SAGE and GALLEX Source Measurements as a Capture-Rate Budget Against Published Values

Year: 2026
Type: article
Abstract: The gallium solar-neutrino detectors SAGE and GALLEX were calibrated with intense radioactive sources, and both measured fewer captures than expected, a deficit that predates the later BEST measurement and rests on independent source runs. This paper combines the two historical source results, states the deficit and its significance, and prices the sterile-neutrino and cross-section readings of the same numbers. The combined historical gallium ratio is 0.85 at 4.243 standard deviations from unity, a deficit of 15 percent requiring a mixing of 0.3. Computed from stated assumptions, not measured. Alongside those, deficit significance stands at 4.243 standard deviations, and deficit in percent at 15 percent.
Language: English
Open Access status: green
OpenAlex ID: W7236021469
FWCI:
Cites:
Cited by:
Related to: 10