Refractory coronary spasm during emergency PCI: serial IVUS documentation and stent- free management — a case report
Year: 2026
Type: preprint
Study design: Case Report
Abstract: Background Coronary artery spasm is an important cause of myocardial infarction in patients without obstructive coronary artery disease. Most spasms respond promptly to intracoronary nitroglycerin; however, refractory spasm that progresses despite nitrate therapy is uncommon and can create a vicious cycle of slow flow and recurrent thrombosis during emergency percutaneous coronary intervention (PCI). Serial intravascular ultrasound (IVUS) documentation of this process has rarely been reported. Case presentation: A 58-year-old man with no conventional cardiovascular risk factors but a history of recurrent resting chest pain presented with aggravated sudden chest pain. Emergency coronary angiography revealed severe stenosis in the distal right coronary artery. Following intracoronary administration of nitroglycerin, no improvement in the stenosis was observed. IVUS revealed a lumen diameter of 3.22 mm at the origin of the posterior descending artery/posterolateral branch, with a minimum lumen area of 3.19 mm 2 . An intraluminal thrombus was present, but no evidence of plaque rupture or dissection was detected. Subsequent IVUS examination revealed further stenosis at the same site (lumen diameter: 2.44 mm; minimum lumen area: 2.75 mm 2 ), which is consistent with progressive coronary artery spasm. Despite multiple attempts at balloon dilation and intracoronary administration of nitroglycerin, the lumen diameter at the site reached its minimum value (1.87 mm) during the procedure. Intracoronary tirofiban and urokinase were administered, and repeated balloon dilatation was performed. Final IVUS showed adequate lumen expansion with a residual mural thrombus. Stent implantation was withheld because no significant fixed atherosclerotic lesion was present. A repeat angiogram after 8 days showed a patent right coronary artery. The patient remained free of chest pain on continued diltiazem therapy (90 mg twice daily) at 4-month follow-up. Conclusions This case demonstrates that coronary spasm can progress despite intracoronary nitroglycerin during emergency PCI, leading to recurrent thrombosis and slow flow. Serial IVUS is valuable for distinguishing functional spasm from structural obstruction and for guiding a stent-free strategy in the absence of a fixed culprit plaque. Recognition of this phenomenon is important in resource-limited settings where intracoronary calcium-channel blocker formulations may not be available.
Source: Research Square
Authors: Lipeng Mao¹, Kai Zhang¹, Ruifeng Jia, Junqiang Cao¹
Language: English
Subfield: Cardiology and Cardiovascular Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7236058912
