Work

Standard-Model-Extension Coefficients from the Stanford Rubidium Atom Interferometer

Year: 2026
Type: article
Abstract: An atom interferometer drops clouds of rubidium atoms and reads their phase, and the absence of any anomalous phase shift limits the coefficients that parametrise Lorentz violation for rubidium atoms. The phase shift is 2 × 10^-6 radians, the leading coefficient comes out at 1 × 10^-9, and the ratio to the published limit is 1. Five coefficients are stated, each the phase divided by its sensitivity, with the second coefficient at 1.25 × 10^-9 and the fifth at 3.333 × 10^-9. The free fall time is 1.2 seconds and the arm separation is 0.01 metres. The result is computed from the published interferometer limit and the stated sensitivities, not measured here, and it is the atom-interferometer anchor of the laboratory bounds in this set.
Language: English
Open Access status: green
OpenAlex ID: W7236074175
FWCI:
Cites:
Cited by:
Related to: 10