Year: 2026
Type: article
Study design: Observational Study
Abstract: Background and Aims Quantification of the soft tissue uptake in 99m Tc‐DPD has emerged as a promising imaging biomarker in ATTRwt. Recent findings suggest a potential role of [ 99m Tc]Tc‐DPD soft tissue uptake in the diagnosis of polyneuropathy in these patients. Methods In this registry study, we analyzed all patients who presented at the Amyloidosis Centre Berlin and underwent a standardized diagnostic protocol comprising a multidisciplinary examination, neuroelectrophysiology, ECG, biomarkers, [ 99m Tc]Tc‐DPD scintigraphy and echocardiography, without other causes of polyneuropathy. We analyzed the planar scans using soft‐tissue‐to‐bone and heart‐to‐hemithorax ratios. We assessed the subcutaneous fat uptake using derived from SPECT/CT. Results Of the 72 patients, 57 ATTRwt patients were included in the analysis. Among these, the prevalence of polyneuropathy and cardiomyopathy was 60% and 95%, respectively. The neurographic pattern was mainly axonal (53%) or mixed (32%). Patients with polyneuropathy showed significantly higher in axillary subcutaneous tissue compared to those without ( p ‐value = 0.002). There was no correlation between extracardiac tracer uptake and polyneuropathy severity by using the NIS. Interpretation Our results indicate that amyloid load in soft tissue may serve as a potential indicator of peripheral neurological involvement. Future studies are required to explore the utility of DPD scintigraphy for outcome assessment in treated patients.
DOI: 10.1111/jns.70183
Language: English
Subfield: Internal Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: hybrid
Estimated APC paid: $4,550
OpenAlex ID: W7236112116