Adaptive Neuro-Fuzzy Inference System (ANFIS)-Based Controller for Unified Power Quality Conditioning (UPQC) in Islanded Microgrid
Year: 2026
Type: article
Abstract: This study investigates the development and performance of an ANFIS-controlled Unified Power Quality Conditioner (UPQC) integrated into a solar photovoltaic-battery islanded microgrid for voltage regulation, harmonic mitigation, transient stability, and active-power balancing in the Tende-Ama Ogu/Bolo distribution system, Rivers State, Nigeria. The study first assessed the solar energy resource at Tende-Ama Community using Global Horizontal Irradiance (GHI) data obtained from the NASA POWER database for January 2024 to August 2026. An average daily GHI of 4.13 kWh/m²/day was obtained, with PV capacity factors of 62.79%, 60.24%, and 60.19% for the assessed 2024, 2025, and 2026 periods, respectively. A MATLAB/Simulink model of the solar-battery islanded microgrid was subsequently developed, comprising a PV array, MPPT-controlled boost converter, DC-AC inverter, BESS with bidirectional boost-buck converter, balanced load, and nonlinear rectifier load. Load-flow analysis of the Tende-Ama Ogu/Bolo distribution system established the baseline voltage profile under heavy loading and identified Bus 5, Bus 10, Bus 13, Bus 14, and Bus 18 as voltage-weak buses, with voltage magnitudes of 93.25%, 92.77%, 93.50%, 91.59%, and 90.72%, respectively. A UPQC was then integrated at the point of interconnection to provide series and shunt compensation. Harmonic assessment showed that the total harmonic distortion of 20.62% was reduced to 1.15% following UPQC compensation. Under transient voltage disturbances, the UPQC dynamically compensated for voltage sag and swell while maintaining a stable load voltage. Under heavy loading, integration of the ANFIS-controlled UPQC improved all bus voltages to within the 0.95–1.05 pu acceptable operating range, with the previously weak buses improved to 99.327%, 99.091%, 99.945%, 99.500%, and 99.536%, respectively. The findings demonstrate that the integrated ANFIS-controlled UPQC and coordinated PV-BESS control strategy provides an effective approach for improving voltage regulation, mitigating harmonic disturbances, supporting transient stability, and maintaining active-power balance in a solar-battery islanded microgrid.
DOI: 10.64388/ire1725278
Authors: YARHERE, Anthony Kevwe, E.C. Obuah, E.D. Ekeriance
Institution: Rivers State University
Language: English
Topic: Power Quality and Harmonics
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: bronze
OpenAlex ID: W7236114563
