Influence of density-modulus relationships on the predicted biomechanical response of subject-specific mandibular finite element models: comparative analysis with experimental test data
Year: 2026
Type: article
Abstract: Introduction Finite element (FE) analysis has become an essential tool for studying the biomechanical behavior of the mandible and predicting the mechanical performance of surgical and restorative interventions. The predictive accuracy of FE models, however, depends on underlying assumptions. Current models often rely on simplified homogeneous material assumptions and lack experimental comparison. Therefore, the present study aims to compare predictions from FE analyses with experimental test data to investigate the influence of heterogeneous density-modulus relationships on the biomechanical response of subject-specific FE models of the human mandible. Methods For this study, experimental testing with a universal testing machine and FE models of three human mandible specimens were developed in parallel. The experimental and computational boundary conditions included a 200 N load on the caudal side of the mandibular angle, embedding the condyles and fixing the incisor teeth or the left first molar for a central or unilateral load case, respectively. In the FE analysis, eight different density-modulus relationships were employed to represent the heterogeneous material of human bone. The global parameter stiffness and the local parameter surface strain were compared across different density-modulus relationships between predicted and experimental results. Results The experimental tests measured the bone stiffness and local surface strain, ranging from 1.6 - 4.1 N/μm and –108.3 - 44.9 μm/m, for the central load case, and from 0.9 ‐ 4.0 N/μm and –104.8 - 60.9 μm/m, for the unilateral load case. The FE analysis predicted them between 4.8 - 13.0 N/μm, –253.1 - 60.9 μm/m for the central load case and 3.2 - 11.1 N/μm, –288.0 - 94.0 μm/m for the unilateral load case. Consistency between experimental tests and FE predictions was better for global stiffness than for local surface strain, with variation depending on the subject and load case. Discussion Given the limitations of our experimental test setup and the simplified assumptions in the FE analysis, no density-modulus relationship used for the FE models consistently reproduced the measured biomechanical experimental data. The results of the FE analysis were highly dependent on the density-modulus relationships used, which highlights the need to conduct sensitivity analyses and further computational studies to develop mandible-specific material models.
Authors: Ann-Kristin Becker(Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Software, Supervision, Validation, Visualization, Writing – original draft, Writing – review & editing), Daniel Thiele(Conceptualization, Data curation, Formal analysis, Investigation, Methodology, Software, Supervision, Validation, Visualization, Writing – original draft, Writing – review & editing), Iman Soodmand(Conceptualization, Formal analysis, Methodology, Software, Supervision, Writing – review & editing), Christopher Jabs(Conceptualization, Methodology, Software, Writing – review & editing), Jessica Hembus(Conceptualization, Data curation, Methodology, Supervision, Validation, Writing – review & editing), Michael Dau(Data curation, Supervision, Validation, Writing – review & editing), Rainer Bader(Funding acquisition, Project administration, Resources, Supervision, Writing – review & editing), Maeruan Kebbach(Formal analysis, Funding acquisition, Methodology, Project administration, Software, Supervision, Writing – review & editing), Jan-Oliver Sass(Conceptualization, Formal analysis, Investigation, Methodology, Project administration, Software, Supervision, Validation, Writing – original draft, Writing – review & editing)
Institutions: Universitätsmedizin Rostock, University of Rostock
Language: English
Subfield: Orthodontics
Field: Dentistry
Domain: Health Sciences
Open Access status: gold
Estimated APC paid: $3,801
Funder: ITI Foundation
OpenAlex ID: W7236281889
