Evaluation of the Efficacy of Reagent Strips in the Rapid Bedside Diagnosis of Meningitis

Year: 2026
Type: article
Study design: Observational Study
Abstract: Background: Meningitis is a major cause of morbidity and mortality worldwide, particularly among children. Early diagnosis and prompt treatment are essential to improve patient outcomes. Conventional cerebrospinal fluid (CSF) analysis requires laboratory facilities and may take longer to provide results. Urinary reagent strips offer a rapid, simple, and convenient method for bedside assessment of CSF parameters.Aim: To evaluate the utility and efficacy of urinary reagent strips (Combur 10) in the rapid bedside analysis of CSF glucose, protein, and leukocyte count and to compare their results with conventional laboratory methods.Materials and Methods: A cross-sectional study was conducted on 100 CSF samples collected from patients with suspected meningitis at Mahatma Gandhi Medical College and Research Institute, Pondicherry, India, from January 2023 to December 2023. CSF glucose, protein, and leukocyte levels were assessed using urinary reagent strips. The results were compared with conventional biochemical assays using an automated analyser and cell counts performed using Neubauer’s chamber. Diagnostic performance was evaluated using sensitivity, specificity, positive predictive value, negative predictive value, Cohen’s kappa coefficient, and receiver operating characteristic (ROC) curve analysis.Results: Among the 100 patients, 58% were male and 42% were female. Bacterial meningitis accounted for 41% of cases, viral meningitis for 56%, and fungal meningitis for 3%. For leukocyte detection, the sensitivity and specificity were 92.86% and 97.22%, respectively, at a cutoff of ≥15 cells/mm³, increasing to 100% for both at higher cutoffs of ≥70 and ≥125 cells/mm³. For protein detection, the sensitivity and specificity were 86.84% and 91.67%, respectively, at ≥30 mg/dL, while both reached 100% at the higher cutoff of ≥300 mg/dL. For glucose detection, the sensitivity and specificity were 46.67% and 100%, respectively, at the cutoff of less than 50 mg/dL, while sensitivity increased to 71.43% with 100% specificity at less than 40 mg/dL. The area under the ROC curve was 95.4% for leukocyte detection, 81.6% for protein detection, and 100% for glucose detection.Conclusion: Urinary reagent strips demonstrate considerable potential as a rapid and convenient bedside screening tool for CSF analysis in suspected meningitis. Their diagnostic performance varies according to the cutoff values used, with higher cutoffs demonstrating improved accuracy for leukocyte and protein detection. Although reagent strips cannot replace conventional laboratory investigations, they may serve as a useful preliminary diagnostic tool, particularly in emergency and resource-limited settings. Further multicentre studies are recommended to validate their diagnostic utility.
Source: STEMedicine
Language: English
Subfield: Microbiology
Open Access status: gold
Estimated APC paid: $1,200
OpenAlex ID: W7236337312
FWCI:
Cites:
Cited by:
Related to: 10