Work

Calibration Error in Virgo During the Third Observing Run: Amplitude and Phase Uncertainty Budget Against Published Values

Year: 2026
Type: article
Abstract: This paper computes a detector noise budget for the instrument named in the title, from stated inputs and named formulas, and tests the result against a published value. The calculation finds that the number of calibration error components is 5.000 components, the calibration component 1 is 3.000 percent, the calibration component 2 is 2.000 percent, the calibration component 3 is 1.500 percent. The ratio of the computed value to the published comparison value is 1.023, so the budget agrees with the published value within the stated uncertainties. The full set of computed quantities is deposited with the paper in machine-readable form, so every number in the text can be reproduced from the deposited script. Computed from stated assumptions, not measured.
Language: English
Open Access status: green
OpenAlex ID: W7236360339
FWCI:
Cites:
Cited by:
Related to: 10