Abstract: This paper computes a detector noise budget for the instrument named in the title, from stated inputs and named formulas, and tests the result against a published value. The calculation finds that the circulating arm power is 200.00 kilowatts, the shot noise at low frequency is 0.0409 zeptostrain per root hertz, the shot noise at 10.0 hertz is 0.0409 zeptostrain per root hertz, the shot noise at 50.0 hertz is 0.0412 zeptostrain per root hertz. The ratio of the computed value to the published comparison value is 1.048, so the budget agrees with the published value within the stated uncertainties. The full set of computed quantities is deposited with the paper in machine-readable form, so every number in the text can be reproduced from the deposited script. Computed from stated assumptions, not measured.