Higher proton conductivity, lower current density: how inlet water vapour shapes the thermal window of a PEM fuel cell
Year: 2026
Type: article
Abstract: Proton exchange membrane fuel cells (PEMFCs) are conventionally operated at 60–80 °C on kinetic and conductivity grounds. Increasing temperature can improve proton transport, while at fixed inlet relative humidity and total pressure it also increases the inlet water-vapour fraction and reduces reactant partial pressures. A validated three-dimensional two-phase model of a 20 cm 2 parallel-channel PEMFC at 150 kPa quantified this competition over 20–90 °C and 20–100% relative humidity (RH). Peak power density reached 0.997 W cm −2 at 40 °C, with 30–50 °C values within 1%, a broad plateau not a sharp optimum, falling 14.3% by 80 °C. Under saturation, heating from 40 to 80 °C raised proton conductivity 62% (6.34 to 10.30 S m −1 ) yet reduced current density 21% (2.16 to 1.71 A cm −2 ), as vapour rose from 4.9% to 31.6% of the gas. At a constant inlet dew point referenced to 40 °C and 50% RH, the peak power density still fell by 26.5% between 40 and 80 °C, showing that increasing inlet vapour dilution is not necessary for the thermal penalty. At 40 °C, peak power density varied by only 0.13% across 20–100% RH. PEMFC thermal setpoints reflect the coupled effects of proton transport, membrane hydration, reactant availability and water management, not temperature alone.
Source: Journal of Power Sources
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: hybrid
Estimated APC paid: $4,230
OpenAlex ID: W7236441132