A Case of Dural Reconstruction Using an Absorbable Dural Substitute for a Dural Defect Caused by a Tiger Bite
Year: 2026
Type: article
Study design: Case Report
Abstract: Absorbable dural substitutes are established dura mater reconstruction materials; however, their suitability for use in contaminated wounds remains unclear. We report a case in which an absorbable dural substitute was used for dural reconstruction in a patient with a dural defect caused by a tiger bite, in which favorable dural reconstruction was achieved. The patient was a woman in her 20s who was attacked by a tiger at a tiger enclosure and transported to our hospital. In addition to multiple systemic injuries, she presented with a left temporal lobe brain contusion, a left temporal bone fracture, a dura mater defect in the left temporal region, and persistent cerebrospinal fluid leakage. We attempted dura mater reconstruction but found the patient's temporal fascia to be contused and contaminated, rendering it unusable for reconstruction. Therefore, we performed dura mater reconstruction using an absorbable dural substitute (DuraGen). As a result, dural reconstruction was achieved without infection or cerebrospinal fluid leakage. When reconstruction using the patient's own tissue is difficult, dural reconstruction using DuraGen may be an alternative option.
Source: NMC Case Report Journal
Institution: Jichi Medical University
Language: English
Subfield: Clinical Neurology
Field: Medicine
Domain: Health Sciences
Open Access status: diamond
OpenAlex ID: W7236447333