Work

Hardware Accelerator or ISA Extension: A Measured Co-Design of a PPG Heart-Rate Accelerator and a Multicycle RISC-V Soft Core

Year: 2026
Type: preprint
Abstract: Wearable pulse oximeters must turn a photoplethysmogram (PPG) into heart rate (HR) and oxygen saturation(SpO2) on very small processors. Adding a dedicated acceleratoris a common answer, but its benefit is rarely measured againsta fair software baseline or against a cheaper instruction-setextension. This paper presents a system on chip (SoC) in which amulticycle RV32I soft core and a purpose-built PPG accelerator(moving-average filter, slope, peak detector and HR divider) sharea memory-mapped interface and read a MAX30102-class opticalsensor through an I2C controller. The same firmware algorithmwas built in four configurations (RV32I, RV32IM, and eachwith the accelerator) and characterised for latency, area, energyand accuracy. Against the RV32IM baseline the acceleratorreduces beat-to-result latency by 1.75× (476 to 272 cycles at50 MHz) and makes it constant, while costing 165 adaptive logicmodules (ALMs) and no DSP blocks on a Cyclone V, against 357ALMs and three DSP blocks for RV32M. The two additions arecomplementary: RV32M speeds the division-heavy SpO2 path by9.9×. The accelerator closes timing at 50 MHz in all corners ofthe SkyWater 130 nm process in 0.066 mm2 and 1.55 mW, ofwhich 99% is clock power. On 53 BIDMC records a model of thefirmware’s detector gives a mean absolute HR error of 2.40 BPM.
Language: English
Open Access status: green
OpenAlex ID: W7236454753
Cites:
Cited by:
Related to: 10