Work

Surrogate Model-Assisted and Load-Dependent Optimization of Prismatic LFP Battery Module Cooling

Year: 2026
Type: article
Abstract: This study examines the offline selection of coolant flow rate and inlet temperature for a fixed eight-cell, 50 Ah prismatic lithium iron phosphate battery module under different loads. A dataset of 100 steady-state CFD cases was used to predict maximum battery temperature, inter-cell temperature difference, and cold-plate pressure drop. Response surface methodology, XGBoost, and Kriging were compared using five-fold cross-validation on 80 training cases and prediction errors on 20 separately generated cases. Kriging achieved the lowest errors for all three responses. The response-specific Kriging models were refitted using all 100 cases and coupled with NSGA-II to generate approximate Pareto candidates at eight loads from 0.5 to 4.0 C. After screening for maximum temperature ≤ 40 °C and inter-cell temperature difference ≤ 5 K, the candidate with the lowest predicted pressure drop was selected at each load. The selected flow rates ranged from 1.000 to 1.008 L/min/plate, with load-specific inlet temperatures. Additional CFD simulations confirmed that all eight combinations met both adopted thermal targets under the original CFD model. Prediction of all three responses required 2.486 ± 0.788 ms per condition, supporting repeated evaluation of operating alternatives.
Institution: Soongsil University
Language: English
Open Access status: gold
Estimated APC paid: $2,896
OpenAlex ID: W7236467769
FWCI:
Cites: 33
Cited by:
Related to: 10