Work

Association of passive posterolateral corner rotational compliance with tibial external-rotation excursion during functional movement: a cross-sectional laboratory study

Year: 2026
Type: article
Study design: Observational Study
Abstract: Importance The posterolateral corner (PLC) is the principal passive restraint to tibial external rotation, but whether PLC compliance relates to cutting external-rotation excursion in uninjured knees remains unclear. Objective The aim of this study is to estimate the association between passive PLC rotational compliance and tibial external-rotation excursion during 45-degree cutting. Design, setting, and participants A single-center, cross-sectional laboratory study was conducted on 33 uninjured athletes (January–February 2026) who underwent passive laxity testing, ultrasound with shear-wave elastography, and three-dimensional motion capture. Exposure PLC rotational compliance (deg/Nm): tibial external rotation under a 10-N·m torque, relative to 0 N·m, divided by torque; mean of two supine trials at each of 30°, 60°, and 90°. Main outcomes and measures Primary outcomes included tibial external-rotation excursion during cutting (peak minus initial-contact angle; mean of three trials). Secondary outcomes included other tasks, kinetics, and ultrasound measures, including fibular collateral ligament (FCL) strain (load-induced elongation/pre-load length). Results Among 33 participants (17 [52%] female; mean [SD] age, 21.4 [2.3] years), compliance decreased from 30° to 90° (−0.34 deg/Nm; 95% CI = −0.37 to −0.30), and external-rotation loading increased FCL strain at 30° by 4.0 percentage points (95% CI, 3.8–4.3). Compliance had high within-session reliability (intraclass correlation coefficient = 0.88–0.93). Greater compliance was associated with greater excursion in unadjusted analysis (β = 3.1 deg per deg/Nm; 95% CI = 0.7–5.6; P = 0.014); after prespecified adjustment, the estimate was attenuated, primarily by sex, was not statistically significant (β = 1.9; 95% CI = −0.6 to 4.4; P = 0.130), and was sensitive to two influential participants. The standardized adjusted compliance coefficient was 0.26 (95% CI = −0.08 to 0.59), compatible with null to large associations. Trial-level estimates were similar for cutting (β = 2.3; 95% CI = −0.2 to 4.8; P = 0.069) and, post hoc , for all tasks pooled (β = 2.4; 95% CI = 0.3–4.6). No secondary association across the three prespecified false-discovery-rate families remained significant after controlling the false discovery rate at 5%. Conclusion and relevance The association between passive PLC compliance and cutting excursion was largely shared with sex; after adjustment, it was neither established nor excluded. In uninjured athletes, when sex is considered, supine passive compliance should not be regarded as interchangeable with dynamic excursion or as a substitute for dynamic assessment.
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: gold
Estimated APC paid: $3,801
OpenAlex ID: W7236491749
FWCI:
Cites: 28
Cited by:
Related to: 10
Parts: 1