Work

In-situ Temperature-Strain Integrated "Stethoscope" for High-Accuracy SOC Estimation and SOH-Assisted Diagnosis of Prismatic Lithium-Ion Batteries

Year: 2026
Type: article
Abstract: Accurate SOC and SOH estimation is vital for safe, reliable BMS operation. Existing methods rely mainly on electrical signals; weak surface strain of prismatic lithium-Ion batteries limits mechanical monitoring. We propose an integrated temperature-strain sensor as an in-situ "stethoscope" for prismatic lithium-Ion batteries, synchronously acquiring surface micro-strain and temperature during cycling. Calibration shows ultra-high strain resolution of 0.04 µε. By using a DNN to fuse strain, temperature, voltage, and current, this multi-source strategy achieved an MAE of 0.6620% and an RMSE of 0.8873% for SOC estimation, representing reductions of 64.68% and 62.38%, respectively, compared to a purely electrical model. Moreover, differential analysis reveals that dε/dV characteristic peaks align closely with dQ/dV peaks, indicating strain inherently reflects electrochemical reaction kinetics. dε/dV shows higher sensitivity to internal battery state changes, offering great potential for SOH diagnosis. These results validate that the temperature-strain diagnostic device enables high-accuracy SOC estimation and provides a promising pathway for mechanical-electrochemical coupled health monitoring in rigid battery enclosures.
Institution: Ningbo University
Language: English
Open Access status: bronze
OpenAlex ID: W7236568772
FWCI:
Cites: 35
Cited by:
Related to: 10