Evaluation of vibration transmissibility and ergonomic usability of anti-vibration gloves at real workstations
Year: 2026
Type: article
Abstract: Exposure to hand transmitted vibration is common in workplaces using hand held-tools and contributes to upper limb disorders, including hand-arm vibration syndrome. Anti-vibration gloves are often the only personal protective equipment available, but their use remains limited because of discomfort and reduced manual dexterity, so glove assessment should extend beyond laboratory testing to real working conditions. This article proposes an extension of ISO 10819 based on eight vibration transmission coefficients determined in situ, together with comfort-related parameters such as dexterity and the force required to bend the fingers. The method was applied at four workstations differing in vibration characteristics, using an ISO 10819-compliant glove of a new design as a case study. Frequency-weighted exposure was reduced by 10–56% depending on the workstation, although at one workstation the results indicated amplification in one of the analysed axes. Compliance with ISO 10819 therefore does not guarantee protection at every workstation.
Source: Ergonomics
Institution: Central Institute for Labour Protection
Language: English
Subfield: Orthopedics and Sports Medicine
Field: Medicine
Domain: Health Sciences
Open Access status: hybrid
OpenAlex ID: W7236607204