Five-Year Postoperative Refractive Outcomes and Predictors After Manual Small-Incision Cataract Surgery in Ghana.
Year: 2026
Type: preprint
Study design: Observational Study
Abstract: Clinical relevance: Reliable refractive outcomes after cataract surgery help optometrists identify residual ametropia, guide spectacle correction and recognise modifiable refractive error. Background This study aimed to characterise postoperative refractive outcomes after manual small-incision cataract surgery, assess refractive accuracy against benchmarks, and identify associated factors. Methods This retrospective audit included patients aged 40 years or older who underwent manual small-incision cataract surgery with intraocular lens implantation from 2021 to 2025 at a district hospital in Ghana. Of 640 operations, 204 records met eligibility and data-completeness criteria, including manifest refraction at 4–6 weeks. Prediction error was the achieved postoperative spherical equivalent minus the intended target; absolute prediction error was its absolute value. Refractive surprise was an absolute prediction error greater than 1.00D. Surgically induced astigmatism was calculated by vector analysis. Results Median postoperative spherical equivalent was − 0.50D (interquartile range − 1.25 to 0.00) and median cylinder was − 1.50D (interquartile range − 2.00 to − 1.00); 92.2% had an astigmatic component. Median surgically induced astigmatism was 1.83D (interquartile range 1.14–2.74), and against-the-rule astigmatism increased from 63.2% to 81.9%. Median absolute prediction error was 0.75D (interquartile range 0.25–1.25); 46.1% were within ± 0.50D and 74.5% within ± 1.00D of target, below benchmark (p = 0.011 and p < 0.001). Refractive surprise occurred in 25.5%. No variable independently predicted refractive surprise; each additional 1.00D of preoperative corneal astigmatism was associated with a 0.12D increase in absolute prediction error (95% confidence interval 0.03–0.22; p = 0.014). Conclusion Postoperative outcomes showed substantial residual astigmatism, refractive accuracy below benchmark thresholds and systematic myopic bias. Facility-specific lens-constant optimisation, astigmatism-informed incision planning and improved completeness of postoperative refraction are practical quality-improvement targets.
Source: Research Square
Institution: University of Cape Coast
Language: English
Subfield: Ophthalmology
Field: Medicine
Domain: Health Sciences
Keywords: manual small incision cataract surgery, refractive outcomes, surgically induced astigmatism, refractive surprise, prediction error, intraocular lens power selection, against-the-rule astigmatism, residual astigmatism, corneal astigmatism, spectacle correction, Ghana, low- and middle-income countries
Open Access status: green
OpenAlex ID: W7236633540