Comparative Outcomes of 3D-Printed Porous Artificial Vertebral Bodies and Titanium Mesh Cages After Single-Level Anterior Cervical Corpectomy and Fusion for Cervical Spinal Stenosis With Hyperextension Injury: A Retrospective Cohort Study

Year: 2026
Type: preprint
Study design: Observational Study
Abstract: Objective To compare the perioperative, clinical, and radiographic outcomes of 3D-printed porous artificial vertebral bodies and titanium mesh cages (TMCs) for anterior column reconstruction after single-level anterior cervical corpectomy and fusion (ACCF) in patients with cervical spinal stenosis combined with hyperextension injury, and to identify factors associated with postoperative subsidence. Methods This single-center retrospective comparative cohort study included 140 consecutive patients who underwent single-level ACCF between 2023 and 2025, with 70 patients in the 3D group and 70 in the TMC group. Baseline characteristics, perioperative parameters, clinical outcomes, radiographic outcomes, and complications were compared between groups. The main radiographic outcomes included subsidence, reconstructed segmental height loss (ΔH), absolute change in the C2–7 sagittal vertical axis (ΔcSVA), loss of the C2–C7 Cobb angle, and fusion rates at 6 and 12 months. Multivariable logistic regression was used to identify factors associated with subsidence. Stabilized inverse probability of treatment weighting (IPTW) was additionally performed as a sensitivity analysis to address measured treatment-selection imbalance. Results The 3D group had a shorter operative time, less intraoperative blood loss, and a shorter hospital stay than the TMC group (all P ≤ 0.002). The JOA recovery rate was higher in the 3D group (78.0 ± 13.8% vs 69.0 ± 14.3%, P < 0.001), whereas postoperative NDI was borderline different (P = 0.050) and VAS reduction was similar between groups (P = 0.544). The 3D group showed a lower subsidence rate than the TMC group (17.1% vs 61.4%, P < 0.001), less height loss (1.0 ± 0.6 vs 2.5 ± 0.9 mm, P < 0.001), a smaller absolute change in cSVA (11.6 ± 3.1 vs 22.0 ± 5.4 mm, P < 0.001), and less loss of the C2–C7 Cobb angle (1.0 ± 0.3° vs 3.1 ± 1.4°, P < 0.001). The 6-month fusion rate was higher in the 3D group (85.7% vs 40.0%, P < 0.001), whereas the 12-month fusion rates were similar (94.3% vs 88.6%, P = 0.366). Multivariable analysis showed that use of a 3D-printed vertebral body was associated with lower odds of subsidence (adjusted OR 0.035, 95% CI 0.010–0.116, P < 0.001). Each 10-HU decrease in the lower adjacent vertebral body (OR 1.189, 95% CI 1.096–1.291, P < 0.001) and each 1-mm increase in immediate postoperative reconstructed height (OR 1.417, 95% CI 1.090–1.840, P = 0.009) were associated with higher odds of subsidence. The IPTW sensitivity analysis yielded a directionally consistent association (OR 0.078, 95% CI 0.032–0.185, P < 0.001). Conclusions In patients with cervical spinal stenosis combined with hyperextension injury undergoing single-level ACCF, use of a 3D-printed porous artificial vertebral body was associated with lower postoperative subsidence, less radiographic change, and a higher early fusion rate than TMC reconstruction. The difference in fusion was no longer significant at 12 months, suggesting a potential benefit mainly in accelerating early fusion rather than increasing the ultimate likelihood of fusion. Lower adjacent vertebral HU values and greater immediate postoperative reconstructed height were also associated with higher odds of subsidence. Because of the retrospective nonrandomized design, these findings require further validation in prospective multicenter studies.
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: green
OpenAlex ID: W7236701608
Cites: 26
Cited by:
Related to: 10