Muscle activity and hip kinematics during robot-assisted hip abduction after total hip arthroplasty: a preliminary single-arm study
Year: 2026
Type: preprint
Study design: Clinical Trial
Abstract: Background This preliminary study examined the technical feasibility of early postoperative robot-assisted hip abduction after total hip arthroplasty and described task-specific differences in muscle activity and hip kinematics. Clinical rehabilitation effectiveness is not established in this report. Methods Forty participants were enrolled, 36 started training, and 35 completed four sessions within two weeks after surgery. Each session included 10 unassisted repetitions followed by 50 assisted repetitions; 10 further unassisted repetitions were performed after session 4. For biomechanical comparisons, the 10 unassisted repetitions were compared with the first 10 HAL-assisted repetitions. Surface electromyography of the gluteus medius and tensor fasciae latae was normalized to each muscle’s maximum unassisted root mean square value within each session. Paired t-tests or Wilcoxon signed-rank tests compared conditions and time points; surgical-approach comparisons were exploratory. Hip abductor force and adverse events were assessed. Results Assisted movement showed greater hip abduction in all four sessions and lower hip flexion in sessions 1–3. Normalized tensor fasciae latae activity was lower in all sessions, whereas normalized gluteus medius activity was lower in sessions 1–3. The normalized gluteus medius/tensor fasciae latae ratio was numerically higher during assistance. The ratio in unassisted movement after session 4 differed from that before session 1 (1.27 versus 1.02; P = 0.006), although session-specific normalization limits longitudinal interpretation. Hip abductor force increased from 8.6 to 11.2 kgf (P = 0.005). No serious adverse events were reported; one participant discontinued because of postoperative wound pain. Conclusions The protocol was deliverable in 35 of 36 participants who started training. Observed EMG and kinematic differences describe performance under repetition-matched but sequential task conditions and do not isolate an effect of robotic assistance. The uncontrolled design cannot distinguish longitudinal changes from natural recovery and concurrent rehabilitation. Clinical benefit, motor learning, and equivalence across surgical approaches remain unestablished. Trial registration Japan Registry of Clinical Trials, jRCTs032240437, registered 28 October 2024.
Source: Research Square
Authors: Fumi Hirose(Conceptualization, Data curation, Formal analysis, Investigation, Resources, Validation, Visualization, Writing – original draft), Tomofumi Nishino(Funding acquisition, Project administration, Resources, Writing – review & editing), Yuichiro Soma, Yukiyo Shimizu(Funding acquisition, Project administration, Writing – review & editing), Shota Yasunaga(Resources), Ryunosuke Watanabe(Resources, Writing – review & editing), Tomohiro Yoshizawa(Resources, Writing – review & editing), Hajime Mishima(Funding acquisition, Resources, Supervision, Writing – review & editing), Yasuhiro Homma(Supervision, Writing – review & editing)
Institutions: University of Tsukuba, Tsukuba Central Hospital
Language: English
Subfield: Surgery
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7236724078