Work

Hydraulic Performance Variation and Anti-clogging Regulatory Mechanisms of an Auto-flushing Emitter for Drip Irrigation under Sediment‑Laden Water Conditions

Year: 2026
Type: preprint
Abstract: Emitter clogging severely limits drip irrigation using sediment-laden water. This study developed a novel auto-flushing emitter (AFE) with deformable elastomers, which switches between normal irrigation and auto‑flushing modes via pressure‑induced deformation that enlarges the flow cross‑section. Three emitter cores (EMI1, EMI2, EMI3) paired with three elastomers (silicone, SI; polyurethane, PU; non-deformable PTFE as the control, CK) were tested under clean water and sediment‑laden water (2 g/L, d50 = 34.84 µm). Under clean water, the AFE flow rate ( q CW ) increased stepwise with inlet pressure ( H 0 ), with an activation pressure threshold ( H j ) of 0.07–0.10 MPa. When H 0 > H j , q CW of the SI-fitted AFEs was 9.18–50.58% higher than that of the CKs. Under sediment‑laden water, the average relative discharge ( Dra ) of all nine emitters declined with operating time, but this decline weakened at higher H 0 and with softer elastomers. At 360 min, Dra of the SI-fitted AFEs exceeded PU-fitted and CKs by 14.2% and 30.2%, respectively. For AFEs, rising H 0 enlarged the flow cross-sectional area ( S ) and reduced mean flow velocity ( v ), whereas v increased in the CKs. Compared with PU-fitted AFEs and CKs, S of SI-fitted AFEs increased by 3.71–6.79% and 66.91–249.13%, respectively, and v (0.24–0.41 m/s) of the three SI-fitted AFEs overlapped the sediment incipient‑motion velocity (0.07–0.70 m/s). Correlation and regression analyses show that expanded S under auto-flushing is the primary driver of improved anti-clogging performance. These findings provide technical support for AFE development and sediment‑laden water drip‑irrigation application.
Language: English
Subfield: Soil Science
Open Access status: green
OpenAlex ID: W7236743668
Cites: 29
Cited by:
Related to: 10