Compensating repair-induced core loss in rewound induction motors by constrained winding redesign: a loss-ratio criterion for repair shops
Year: 2026
Type: preprint
Abstract: Burn-off stripping during rewinding can raise the core loss of an induction motor, and repair guidance accepts increases of up to 20 %. This paper asks how much of that loss a redesigned stator winding can recover. A 2D finite-element model of an open-data 3.7 kW four-pole motor is calibrated on no-load and locked-rotor tests and transferred to an equivalent circuit, with which 345 rewinding designs are evaluated under slot-fill, starting-current and torque limits. For this motor, recovering the rated efficiency at a 20 % core-loss increase needs 3.4–4.8 % more copper area, 9–13 % at +50 %, and about 16 % at half load. The need is governed by the core-to-stator-copper loss ratio r. Where the criterion gives a ≤ 1.5, a first-order loss balance in r reproduces the model within −8 to +3 percentage points (pp) of copper area, and within +0.6 to +2.4 pp for four IE2/IE3 motors of 7.5–110 kW built from published loss data; with second-order flux-feedback terms it overestimated the requirement in every equivalent-circuit case examined. Measured loss segregations of 20 rewound EASA/AEMT motors (one faulty core excluded) show r = 0.37–1.04 and best-practice core-loss changes of −8 to +18 %. For IE2/IE3 motors with r ≈ 0.5–0.75, a 20 % increase would require 10–17 % more copper, while 5 % copper headroom absorbs only 7–11 % (4–17 % with uncertain inputs). Near the 20 % limit, modern motors therefore depend on keeping core damage small.
Source: Research Square
Author: Mert Ekiz
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: green
OpenAlex ID: W7236775591
