Field evaluation of the Automated Hematology Analyzer XN-31 using blood samples from asymptomatic residents in a malaria-endemic area of Thailand: importance of sample transport and temperature control
Year: 2026
Type: preprint
Abstract: Background The Automated Hematology Analyzer XN-31 can readily quantify the number of malaria parasite–infected red blood cells (MI-RBCs) within approximately one minute using flow cytometry technology, and it has already demonstrated clinical utility for malaria patients in both endemic and non-endemic settings. Recently, asymptomatic carriers with low-density parasitemia in endemic regions have been identified as significant reservoirs contributing to ongoing malaria transmission. Therefore, field-based malaria surveys in endemic areas, including epidemiological investigations of asymptomatic infections, are important for malaria control. Methods To evaluate the feasibility and limitations of the XN-31 use under real-world field conditions, we collected a total of 1,799 blood samples from asymptomatic residents in a malaria-endemic area along the Thailand–Myanmar border during five field trips conducted between January 2021 and May 2022. Samples were transported within the same day to a central laboratory in Bangkok. XN-31 measurements were performed after transport, together with microscopy and rapid diagnostic tests (RDTs). Dried blood spots were also sent to Japan for PCR analysis. Results Microscopy detected one P. vivax –positive case. In contrast, PCR identified 2 P. falciparum and 4 P. vivax infections, whereas all RDT results were negative. The XN-31 detected 5 MI-RBC–positive samples, of which only one was confirmed as P. vivax –positive by both microscopy and PCR. Among the XN-31 measurements, 176 samples were flagged as “MI-RBC Abn Scattergram,” indicating the presence of unidentified particles in the scattergram that prevented proper interpretation. Following protocol adjustments for the transport of whole blood samples to Bangkok, the MI-RBC Abn Scattergram rate in XN-31 decreased from 23.8% (first trip) to 4.6% (fifth trip). Lower frequencies of MI-RBC Abn Scattergram results were observed following modifications to collection-to-analysis time, transport procedures, cooling methods, and transport temperature management. Conclusions In conclusion, although several operational challenges were encountered during field application, the XN-31 may be applicable to malaria surveys in endemic areas when appropriate sample handling and transport conditions are ensured.
Source: Research Square
Language: English
Topic: Malaria Research and Control
Field: Medicine
Domain: Health Sciences
Open Access status: green
OpenAlex ID: W7236819745
