Enhancing adsorption refrigeration system efficiency via mass recovery: Experimental insights
Year: 2026
Type: article
Abstract: This study experimentally investigates a two-bed adsorption refrigeration system using activated carbon–methanol as the adsorbent–refrigerant pair, with emphasis on the effect of mass recovery on cycle performance. Mass recovery utilizes the pressure difference between the desorbing and adsorbing beds by transferring high-pressure methanol vapor from the desorbing bed to the cooler adsorbing bed during the bed switching period. Experiments were conducted without mass recovery and with mass-recovery durations of 155, 180, and 205 s. The results show that a mass-recovery duration of 180 s provides the optimum cycle performance. The COP increased from 0.102 without mass recovery to 0.116 with 180 s of mass recovery, corresponding to an improvement of 13.72%. The results demonstrate that appropriate selection of mass-recovery duration can enhance the performance of a two-bed adsorption refrigeration system while utilizing the pressure differential between the beds during the switching process.
Source: Next Chemical Engineering
Authors: Ashok Verma, Gulshan Sachdeva
Institution: National Institute of Technology Kurukshetra
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: hybrid
Estimated APC paid: $1,250