Work

Diagnostic performance of dual-phase photon-counting detector for localization of parathyroid adenomas after inconclusive first-line imaging

Year: 2026
Type: article
Study design: Observational Study
Abstract: OBJECTIVES: To evaluate diagnostic performance, radiation dose, and quantitative spectral characteristics of dual-phase photon-counting CT (PCD-CT) for parathyroid adenoma localization after inconclusive first-line imaging. MATERIALS AND METHODS: F]FECh PET/CT and dual-phase PCD-CT with arterial and venous acquisitions. Three radiologists, blinded to clinical and reference-standard information, retrospectively assessed arterial and portal-venous 40- and 70-keV images and VNC reconstructions. The reference standard comprised surgery/histopathology with biochemical confirmation, concordant PET/CT with persistent biochemical disease in nonsurgical positive patients, or clinical/biochemical resolution in negative patients. Lesion-level sensitivity, positive predictive value (PPV), and interreader intraclass correlation (ICC) were calculated. Aorta-normalized attenuation and wash-in and wash-out metrics were compared among adenomas, thyroid tissue, and lymph nodes. RESULTS: Forty-nine patients (mean age, 64.2 ± 10.9 years; 42 women) were included, with 45 patients having 49 reference-standard-positive lesions. PCD-CT lesion-level sensitivity was 67.3%-83.7%, and PPV 67.3%-90.0%, with an interreader agreement of 0.506. Aorta-adjusted wash-out was greater in adenomas (27.2%) than in thyroid (20.2%) and lymph nodes (-3.1%; both p < 0.001). Arterial adenoma-thyroid attenuation and wash-in overlapped between adenomas did not differ significantly (arterial p = 0.615 and thyroid tissue. 0.945 at 40 and 70 keV; wash-in p = 0.363). Mean estimated effective dose was 1.23 ± 0.47 mSv. CONCLUSION: Dual-phase PCD-CT provided reader-dependent parathyroid localization at low radiation dose in a difficult second-line cohort. Quantitative wash-out may aid differentiation from thyroid and lymph-node mimics but requires prospective threshold validation. KEY POINTS: Question Inconclusive first-line imaging complicates parathyroid lesion localization. Findings Reader sensitivity ranged from 67.3% to 83.7% at 1.23 mSv. Critical relevance statement Aorta-adjusted wash-out differed among parathyroid lesions, thyroid tissue, and lymph nodes.
Language: English
Subfield: Surgery
Field: Medicine
Open Access status: gold
Estimated APC paid: $3,290
OpenAlex ID: W7236843837
FWCI:
Cites: 30
Cited by:
Related to: 10