A thermal model of a 52 kW traction permanent magnet synchronous motor from documentation and test-bench electrical data: Modelica model, virtual sensors, temperature forecasting and permissible load on the open Electric Motor Temperature data set
Year: 2026
Type: article
Abstract: The open Electric Motor Temperature data set of Paderborn University contains 185 h of test-bench recordings of a 52 kW traction interior permanent magnet synchronous motor (IPMSM): 69 load profiles sampled every 0.5 s. We show how a physics-based model, built from documentation and refined with electrical data of the test bench itself, solves practical tasks: virtual temperature sensors, forecasting under a known load profile, time to threshold, replacement of a failed sensor and permissible load. Model. Our model synthesis method built a Modelica model from the datasheet: a quasi-static dq electromagnetic part, losses by kind and a 7-node thermal network of standard-library primitives. Missing data were taken from bench measurements. The permanent-magnet flux linkage (59.5 mVs,−0.121 %/K), the inductances and the copper resistance were identified from controller voltages and currents. Thermal parameters were refined by a portfolio of methods of the ADAO library: global search and local refinement of every solution found, with selection of several distinct optima. Correcting the model with data. A node-by-node error analysis revealed underestimated winding heat capacity and a wrong coolant boundary. After the correction the cross-validated error fell from 9.71 to 6.73 K², for the magnets from 24.7 to 13.7 K². The parameters converged to the values predicted by the analysis. Tasks (held-out set, generalisation profiles G): open loop — 5.8 K² mean error over four temperatures; virtual magnet sensor (model and voltage-based flux observer in a Kalman filter) — 2.8 K RMSE against 4.7–5.5 K for the same model before the correction; winding forecast at 5–60 min — 2.3–2.6 K, magnets at 15–60 min — 3.9–4.3 K against 11–34 K for persistence; time to threshold — median error 11 s for the winding and 1.7 min for the magnets; a failed stator thermocouple is reconstructed with 1.2–2.1 K error; a stuck sensor is detected within 6–8 min without false alarms. The model is exported as an FMU that matches OpenModelica to 0.0004 K. The initial model was tested blind under a pre-registered protocol. The corrected model and the tasks on it were computed on the held-out set after the analysis and are labelled as not blind.
Authors: Troshin, V.;, Komakhidze, I.;, Abakarov, A.
Language: English
Subfield: Electrical and Electronic Engineering
Field: Engineering
Domain: Physical Sciences
Keywords: interior permanent magnet synchronous motor, traction motors, thermal modeling, Modelica, temperature prediction, permissible load, sensor fault detection, permanent magnet temperature, winding temperature, electromagnetic simulation, parameter estimation, thermal network, test bench measurements, loss modeling
Open Access status: green
OpenAlex ID: W7236847963