Surface Vibration near Twin Metro Tunnels in Layered Ground: Peak Amplification and Spatial Redistribution
Year: 2026
Type: article
Abstract: This study examines how an unloaded neighbouring metro tunnel modifies surface vibration in layered ground using a symmetry-reduced two-and-a-half-dimensional finite element–method of fundamental solutions–direct stiffness method (2.5D FEM–MFS–DSM) model. The formulation is assessed against an independent semi-analytical benchmark and Beijing Metro Line 10 measurements, with a mean absolute error of 1.45 dB at three surface receivers. Under coupled train excitation, the neighbouring tunnel increases the maximum Z-vibration level by 1.85 dB in the baseline configuration. At a tunnel centre depth of 24.2 m, increasing the spacing from 12 to 15 m leaves the maximum-level increment near 1.73 dB, while shifting the peak by 4 m and narrowing the 1 dB high-response region from 8.0 to 6.5 m. Complex-field analysis under a common 80 Hz moving unit load shows how the modification magnitude, relative phase, and original response level govern local changes and the surface maximum. At the baseline depth, among the three spacings examined in detail (12, 15, and 18 m), the largest maximum-response increment occurs at 15 m under the unit load but at 12 m under coupled train excitation. The results support assessing both peak magnitude and spatial redistribution when characterising ground vibration input to nearby buildings.
Source: Buildings
Authors: Chunhui Wang, Kai Sun, Tailong Hu
Language: English
Subfield: Mechanical Engineering
Field: Engineering
Domain: Physical Sciences
Open Access status: gold
Estimated APC paid: $3,137
Awards: G9001398683, G9001399159
OpenAlex ID: W7236867167