Work

Anemia at extubation: association with reintubation, practices over time and impact on respiratory effort

Year: 2026
Type: preprint
Study design: Observational Study
Abstract: Background: Anemia is common in critically ill patients and may contribute to extubation failure by impairing oxygen delivery and increasing respiratory effort. However, practices are understudied and the impact of anemia on extubation remains poorly understood. We aimed to assess the association between low hemoglobin and extubation outcomes, clinical practices regarding hemoglobin levels at extubation, and the impact on respiratory effort. Methods: We first conducted a retrospective analysis of prospectively collected data from consecutive adults extubated after ≥24 hours of invasive mechanical ventilation in a tertiary intensive care unit between 2016 and 2024. Patients were categorized according to hemoglobin at extubation <9 or ≥9 g/dL, which defined the primary exposure. The primary outcome was 7-day reintubation, assessed using the Aalen–Johansen estimator and Fine–Gray models, with death as a competing event. Secondly, the temporal trend in hemoglobin level at extubation was assessed using restricted cubic splines. Thirdly, we performed a post hoc analysis of two physiological randomized controlled trials evaluating inspiratory effort using esophageal pressure measurements before and after extubation. The association between pre-extubation hemoglobin and changes in inspiratory effort after extubation was assessed using adjusted linear regressio Results: A total of 1445 patients in the observational cohort and 128 patients in the physiological cohort were included. The 7-day cumulative incidence of reintubation was 21.6% (95%CI, 18.2–25.1%) in patients with hemoglobin <9 g/dL and 23.5% (95%CI, 20.8–26.3%) in those with hemoglobin ≥9 g/dL. After adjustment, hemoglobin <9 g/dL was not associated with 7-day reintubation (sHR 0.95, 95%CI 0.76–1.18; p=0.640). The median hemoglobin level at extubation decreased over time, from 9.9 g/dL in 2016 to 9.2 g/dL in 2024 (p-for-trend=0.048). Inspiratory effort increased in overall physiological cohort population by 59% across extubation, and lower hemoglobin was associated with a slightly greater increase, although not statistically significant (pressure-time-product per minute +7.4% per 1-g/dL hemoglobin decrease; 95%CI, −3.3% to 18.2%; p=0.174). Conclusions: Low hemoglobin was not independently associated with extubation failure. Hemoglobin levels at extubation decreased over time, suggesting more liberal extubation practices. Lower hemoglobin showed only a modest trend toward increased post-extubation inspiratory effort. Trial registration: ClinicalTrials.gov NCT01616901 (2012, June 4 th ), and NCT04222569 (2019, December 9 th )
Language: English
Field: Medicine
Open Access status: green
OpenAlex ID: W7237185604
Cites: 33
Cited by:
Related to: 10